Emergency Lighting Testing
Professional emergency lighting testing and maintenance for fire safety compliance in Eastbourne and East Sussex.

Emergency Lighting Testing in Eastbourne
Ensure your premises meet fire safety regulations with professional emergency lighting testing. D J Fox Electrical provides comprehensive testing and maintenance of emergency exit signs and safety lighting systems throughout East Sussex.
What We Provide
- Monthly functional testing - Verify all lights activate properly
- Annual deep discharge testing - Battery capacity verification
- Emergency lighting maintenance - Battery replacement and repairs
- Exit sign testing - Brightness and legibility verification
- Compliance documentation - Test records for fire safety audits
- Defect reporting - Identification and remediation planning
- System upgrades - Modern LED systems replacing older technology
- Full compliance support - Peace of mind for regulatory requirements
Why Choose D J Fox Electrical?
- NICEIC Approved with 15+ years emergency lighting experience
- Expert in fire safety regulations and standards
- Knowledge of BS 5266-1 emergency lighting standards
- Detailed testing reports and documentation
- Rapid response for failed systems
- 24/7 emergency service
- Serving Eastbourne, Brighton, Hastings, Lewes, Hailsham and all East Sussex
Legal Requirements for Emergency Lighting
Emergency lighting is legally required in many premises:
Commercial Premises
- BS 5266-1 standards apply
- Buildings with emergency exits must have lighting
- Workplaces with 50+ employees (heightened requirements)
- Monthly testing mandatory
- Annual deep discharge testing required
Educational Facilities
- Schools and universities must have emergency lighting
- Tested as part of fire safety procedures
- Staff training on testing procedures
- Records maintained for Ofsted inspections
- Regular maintenance essential
Healthcare Facilities
- Hospitals and care homes must comply
- More stringent testing requirements
- Critical for patient safety during evacuation
- Monthly and quarterly testing typical
- 24-hour monitoring may be required
Rental Properties (HMO)
- Multiple-occupancy homes require emergency lighting
- Minimum standards apply
- Annual testing typically required
- Landlord compliance mandatory
- Insurance requirements often exceed legal minimum
Event Venues
- Theatres, cinemas, music venues
- Event-specific emergency lighting requirements
- Testing before public events
- Professional management essential
- High consequences for failures
Failure to Comply
- Prosecution under Health and Safety at Work Act
- Fines up to £20,000 per offence
- Imprisonment possible in serious cases
- Insurance liability in event of incidents
- Reputation damage and loss of business
Emergency Lighting Standards
Professional emergency lighting must meet BS 5266-1:
Specification Requirements
- Minimum illumination levels (1 lux at floor level on exit routes)
- Maximum ceiling height limitations
- Coverage of all exit routes and hazard areas
- Distance between exit signs (typically 7-10 metres max)
- Alternative power sources (batteries or generators)
- Automatic activation on mains power failure
System Components
- Emergency power supply (battery backup)
- Exit signs and directional arrows
- Illuminated pathway lighting
- Normally unenergised lighting (NUL) systems
- Manual override and testing controls
Installation Standards
- Professional installation by qualified electricians
- Proper circuit separation from general lighting
- Adequate battery capacity for evacuation duration
- Protected wiring routes (fire-resistant cable)
- Regular maintenance and testing regime
Types of Emergency Lighting Systems
Self-Contained Units
- Individual light with integral battery
- Activates on mains failure
- No interconnection with other lights
- Suitable for small premises
- Lower cost option
Central Battery Systems
- Shared battery supply for multiple lights
- All lights coordinated from central unit
- More economical for large premises
- Professional appearance
- Better integrated control
Generator-Backed Systems
- Automatic generator starts on power failure
- Ideal for critical applications
- Provides extended emergency power
- More expensive installation
- Requires maintenance contracts
Exit Sign Systems
- Illuminated exit direction arrows
- Must be visible from any position in room
- "EXIT" and directional arrows clearly marked
- Proper colour and brightness standards
- Alternative exit direction identification
Testing Procedures
Monthly Function Test
- Simulate mains power failure
- All lights activate immediately
- Exit signs illuminate
- No flickering or delayed activation
- Duration: 30 seconds minimum
Quarterly Inspection
- Physical condition check
- Lens cleanliness verification
- Mounting security inspection
- Battery condition assessment
- Documentation of observations
Annual Deep Discharge Test
- Disconnect mains power completely
- Lights must stay on for minimum duration (3-5 hours typical)
- Battery capacity measurement
- Load testing at rated capacity
- Battery replacement if insufficient capacity
5-Year Extended Testing
- In-depth electrical testing of all components
- Battery analysis and replacement
- Full system functionality review
- Professional report and recommendations
- Certification of compliance
Common Testing Issues
- Failed lights - Bulb failure, battery degradation
- Inconsistent illumination - Lens dirt, aging bulbs
- Missing exit signs - Signage removed or obscured
- Blocked routes - Emergency route obstructed
- Poor battery condition - Not holding charge properly
- Inadequate coverage - New exit routes added without lighting
- Lack of records - No documentation of testing history
- Expired testing - Testing not performed on schedule
Maintenance and Battery Care
Emergency lighting systems require regular maintenance:
Bulb Maintenance
- Replace when reaching end of life (typically 10,000+ hours)
- Keep lenses clean (quarterly)
- Avoid touching bulbs (skin oils damage halogen)
- LED replacements (longer life, lower heat)
Battery Care
- Check charging system quarterly
- Verify battery holding charge
- Replace batteries every 3-5 years typically
- Keep connections clean and tight
- Avoid overcharging (shortens battery life)
System Testing
- Monthly functional tests mandatory
- Quarterly physical inspections
- Annual deep discharge testing
- 5-yearly professional review
- Documented testing schedule
Upgrading to LED Emergency Lighting
Modern LED systems offer advantages:
Benefits of LED Emergency Lighting
- 25,000+ hour lifespan (5+ years between replacement)
- Lower power consumption (extends battery runtime)
- Reduced heat generation
- More reliable and durable
- Environmental advantages (lower energy use)
- Better light quality and consistency
Retrofit Costs
- LED unit replacement - £150-£300 per unit
- Battery upgrade - £50-£150 if needed
- Labour for installation - £100-£200 per unit
- Worthwhile investment for reduced maintenance
Service Coverage
Available throughout Eastbourne, Brighton, Hastings, Lewes, Hailsham, and all East Sussex locations. We handle offices, schools, hospitals, care homes, venues, and all commercial premises.
Pricing
Emergency lighting testing costs:
- Single site monthly test - £80-£150 per visit
- Quarterly inspection - £120-£200 per visit
- Annual deep discharge testing - £150-£300 per site
- Small premises (5-10 lights) - £200-£400 annually
- Medium premises (10-20 lights) - £400-£700 annually
- Large premises (20+ lights) - £700-£1,500+ annually
- Emergency light replacement - £150-£300 per unit
Final pricing depends on:
- Number of emergency lights
- System complexity
- Testing frequency required
- Maintenance needs
- Upgrade requirements
- Site accessibility
Compliance Documentation
We provide comprehensive records:
- Monthly test certificates - Proof of regular testing
- Annual test reports - Detailed findings and recommendations
- Battery test results - Performance and replacement recommendations
- Defect logs - Issues identified and remediation status
- Maintenance records - All work performed documented
- Compliance statements - Certification of standards compliance
Get Your Free Emergency Lighting Assessment
Contact D J Fox Electrical for a free emergency lighting assessment. We'll evaluate your system, determine testing requirements, and provide a maintenance proposal.
Phone: Available 24/7 for emergency lighting support Email: Describe your premises and requirements Site Visit: Book your free assessment today
Ready for Professional Emergency Lighting Testing?
Contact D J Fox Electrical today for a free quote. Our expert team is ready to help with your emergency lighting testing needs.